Ai R2 2L Compact Benchtop Glass Reactor
The Ai R2 2L Single Glass Reactor is a compact, reliable, and versatile benchtop reaction system designed for laboratory-scale synthesis, research, formulation, and process development.
Featuring a 2L high-borosilicate glass jacketed vessel, the R2 provides excellent chemical resistance and clear visibility of the reaction process. Its compact footprint makes it particularly suitable for laboratories where bench space is limited, while still providing the essential functions of a full jacketed reactor system.
The reactor features adjustable mechanical stirring, a constant-pressure addition funnel, and an efficient glass condenser, allowing controlled mixing, reagent addition, reflux, and solvent recovery. When connected to a suitable heating/cooling circulator and vacuum pump, the R2 can provide a controlled temperature and vacuum environment for a wide range of small-scale laboratory processes.
Built with durable borosilicate glass, chemical-resistant PTFE components, and a stainless-steel reinforced PTFE agitator, the R2 is designed for dependable day-to-day laboratory operation and easy process observation.

Features
Compact 2L benchtop design – provides full jacketed reactor functionality while occupying minimal laboratory space.
Reliable laboratory performance – designed for routine synthesis, R&D, formulation, and small-batch processing.
High-borosilicate glass reactor vessel – offers excellent chemical resistance, thermal performance, and clear process visibility.
Jacketed vessel design – connects to an external heating or cooling circulator for controlled reaction temperatures.
Adjustable mechanical stirring – provides flexible mixing speeds for different reaction conditions and material viscosities.
PTFE agitator with stainless-steel reinforcement – combines excellent chemical resistance with mechanical durability.
Constant-pressure addition funnel – allows reagents and liquids to be introduced gradually at a controlled rate.
Efficient glass condenser – large cooling surface supports effective reflux, condensation, and solvent recovery.
Vacuum-capable operation – suitable for reduced-pressure applications when paired with an appropriate vacuum pump.
Digital speed and temperature display – provides convenient real-time monitoring during operation.
Chemical-resistant PTFE sealing components – designed for durability and compatibility with a wide range of laboratory chemicals and solvents.
Easy to operate and maintain – a straightforward reactor configuration well suited to everyday laboratory use.
AU-based service and support – backed by a one-year warranty with local parts, technical assistance, and after-sales support.
Typical Applications
Ideal for chemical synthesis, pharmaceutical research, material development, formulation, crystallisation, extraction, reflux, solvent recovery, mixing, and general laboratory R&D.
The Ai R2 is particularly suited to universities, research laboratories, start-ups, and industrial R&D facilities looking for a compact and dependable 2L glass reactor for small-scale reaction work.
Your safety is important to us! Please use caution when operating. Users of glass reaction equipment must take all necessary precautions to avoid contact with rotating parts, particularly the entanglement of loose clothing, hair, necklaces, or other jewelry. Under these circumstances, the winding action of the rotating parts can draw the user(s) into the apparatus, resulting in the breakage of glassware, burns, and/or chemical exposure. Extra caution must also be taken when operating with air-reactive materials, especially under vacuum. A leak can draw air into the apparatus and cause a violent reaction to occur.
| Specifications | R2 | R5 | R10 | R20 |
|---|---|---|---|---|
| Electrical requirements | 220–240 V, 50/60 Hz, single phase | 220–240 V, 50/60 Hz, single phase | 220–240 V, 50/60 Hz, single phase | 220–240 V, 50/60 Hz, single phase |
| Power | 70 W | 130 W | 90 W | 90 W |
| 200°C heating jacket power (non-jacketed glass reactors only) | — | — | — | 220–240 V, 2,100 W |
| Reaction glass vessel capacity | 2 L | 5 L | 10 L | 20 L |
| Cooling/heating jacket capacity (jacketed reactors only) | 1.38 L | 3.5 L | 3 L | 6 L |
| Glass vessel temperature range | −120°C to 200°C | −120°C to 200°C | −120°C to 200°C | −120°C to 200°C |
| Maximum jacket pressure | 0.08 MPa | 0.08 MPa | 0.03 MPa | 0.03 MPa |
| Vacuum level | 300 torr | 300 torr | <30 torr (40 mbar) | <30 torr (40 mbar) |
| Vacuum gauge | Mechanical | Mechanical | Mechanical | Mechanical |
| Vacuum sealing | PTFE | PTFE | Glass or PTFE | Glass or PTFE |
| Rotation controller | Located on the motor itself | Located on the motor itself | Digital controller with variable frequency drive; rotation speed: 50–500 rpm | Digital controller with variable frequency drive; rotation speed: 50–500 rpm |
| Temperature display | Located on the motor itself | Located on the motor itself | Digital controller display | Digital controller display |
| Agitator | 4 blades with a 45° pitch | 4 blades with a 45° pitch | Anchor design, type-304 stainless steel reinforced PTFE | Anchor design, type-304 stainless steel reinforced PTFE |
| Vessel head | Domed with 5 ports | Domed with 5 ports | Domed with 5 ports | Domed with 5 ports |
| Drain valve | Zero dead space with a flat flange clamp | Zero dead space with a flat flange clamp | Flush seal design with large opening and flat flange clamp | Flush seal design with large opening and flat flange clamp |
| Condenser | Single-cooling coil design | Single-cooling coil design | Single-cooling coil design | Single-cooling coil design |
| Funnel | Pressure equalizing | Pressure equalizing | Pressure equalizing | Pressure equalizing |
| Glass material | High borosilicate glass 3.3 | High borosilicate glass 3.3 | High borosilicate glass 3.3 | High borosilicate glass 3.3 |
| Unit dimensions (W × D × H) | 430 × 460 × 1,220 mm | 430 × 460 × 1,220 mm | 460 × 580 × 1,980 mm | 510 × 690 × 2,030 mm |
| Frame dimensions (W × D × H) | 430 × 460 × 1,140 mm | 430 × 460 × 1,140 mm | — | — |
| Shipping dimensions (W × D × H) | 610 × 510 × 1,400 mm | 610 × 510 × 1,400 mm | 610 × 1,700 × 660 mm | 610 × 1,910 × 790 mm |
| Shipping weight | 63 kg | 70 kg | 109 kg | 119 kg |
| Compliance | RCM, CSA (CE, UL optional) | RCM, CSA (CE, UL optional) | RCM, CSA (CE, UL optional) | RCM, CSA (CE, UL optional) |
| Specifications | R50 | R100 | R150 | R200 |
|---|---|---|---|---|
| Electrical requirements | 220–240 V, 50/60 Hz, single phase | 220–240 V, 50/60 Hz, single phase | 220–240 V, 50/60 Hz, single phase | 220–240 V, 50/60 Hz, single phase |
| Power | 140 W | 250 W | 750 W | 750 W |
| 200°C heating jacket power (non-jacketed glass reactors only) | 220–240 V, 3,500 W | 220–240 V, 6,300 W | 220–240 V, 8,000 W | 220–240 V, 8,000 W |
| Reaction glass vessel capacity | 50 L | 100 L | 150 L | 200 L |
| Cooling/heating jacket capacity (jacketed reactors only) | 16 L | 30 L | 45 L (approx.) | — |
| Glass vessel temperature range | −80°C to 200°C | −80°C to 200°C | −110°C to 200°C | −110°C to 200°C |
| Maximum jacket pressure | 0.03 MPa | 0.03 MPa | 0.03 MPa | 0.03 MPa |
| Vacuum level | <30 torr (40 mbar) | <30 torr (40 mbar) | 20 torr | 20 torr |
| Vacuum gauge | Mechanical | Mechanical | Mechanical | Mechanical |
| Vacuum sealing | Glass or PTFE | Glass or PTFE | Glass or PTFE | Glass or PTFE |
| Agitator | Anchor design, type-304 stainless steel reinforced PTFE | Anchor design, type-304 stainless steel reinforced PTFE | Impeller, 304 stainless steel with PTFE liner | Impeller, 304 stainless steel with PTFE liner |
| Drain valve | Flush seal design with large opening and flat flange clamp | Flush seal design with large opening and flat flange clamp | Flush seal design with large opening and flat flange clamp | Flush seal design with large opening and flat flange clamp |
| Funnel | Pressure equalizing | Pressure equalizing | Pressure equalizing | Pressure equalizing |
| Drain port ground clearance | 320 mm | 340 mm | 430 mm | 430 mm |
| Unit dimensions (W × D × H) | 660 × 840 × 2,160 mm | 710 × 1,070 × 2,410 mm | 1,220 × 1,040 × 2,770 mm | 1,220 × 1,040 × 2,770 mm |
| Shipping dimensions (W × D × H) | 640 × 2,110 × 1,070 mm | 660 × 2,240 × 1,140 mm | 1,220 × 1,040 × 2,770 mm | 1,220 × 1,040 × 2,770 mm |
| Mobile splash bin | — | — | 520 × 690 × 180 mm | 520 × 690 × 180 mm |
| Shipping weight | 150 kg | 177 kg | 395 kg | 395 kg |
| Compliance | RCM, CSA (CE, UL optional) | RCM, CSA (CE, UL optional) | RCM, CSA (CE, UL optional) | RCM, CSA (CE, UL optional) |
Operating Conditions
| Parameter | Operating Condition |
|---|---|
| Ambient Temperature | 5–40°C |
| Relative Humidity | Maximum 80% RH at temperatures up to 30°C, decreasing linearly to 50% RH at 40°C |
| Mains Supply Voltage Fluctuation | Up to ±10% of the nominal voltage |
| Transient Overvoltage | Up to Overvoltage Category II levels |
| Temporary Overvoltage | Temporary overvoltage may occur on the mains supply |
| Pollution Degree | Pollution Degree 2 under normal operating conditions |
Note 1: Transient overvoltage levels are typical for equipment supplied from building wiring.
Note 2: More restrictive operating conditions may be specified where required; however, the equipment must remain safe under the normal environmental conditions stated above.